page 1
page 2
page 3
page 4
page 5
page 6
page 7
page 8
page 9
page 10
page 11
page 12
page 13
page 14
page 15
page 16
page 17
page 18
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 37
page 38
page 39
page 40
page 41
page 42
page 43
page 44
page 45
page 46
page 47
page 48
page 49
page 50
page 51
page 52
page 53
page 54
page 55
page 56
page 57
page 58
page 59
page 60
page 61
page 62
page 63
page 64
page 65
page 66
page 67
page 68
page 69
page 70
page 71
page 72
page 73
page 74
page 75
page 76
page 77
page 78
page 79
page 80
page 81
page 82
page 83
page 84
page 85
page 86
page 87
page 88
page 89
page 90
page 91
page 92
page 93
page 94
page 95
page 96
page 97
page 98
page 99
page 100
page 101
page 102
page 103
page 104
page 105
page 106
page 107
page 108
page 109
page 110
page 111
page 112

ICopyright ANGLO NORDIC BURNER PRODUCTS LIMITED 201099Cross Reference & Conversion DataOil Pumps Interchange List - ContinuedDeltaRefDanfossRefHP TechnikRefSuntecRefFuelmasterRefPreviousFuelmasterRefV1LL1RSLB 028 070 L4032AE 47D 7378V1LL-Mono (red label)ILGBLKV1LR1RSLB 028 070 I 4030AE 47C 7368V1LR-Mono (red label)OLGBRKV1LR2MSLB 032 071 B 3101MS10 L3 071 G 0125AN 47C 7328V1LRC/VOLRCMinimaster (green label)ILGBROLGBRV1RL2RSLB 028 070 L4040AN 47C 7218VM1RL1BFP11R3MS11R3AS 47BVM1LR2MSL032/MS 11L3BFP11L3AS 47CAL35CVM1LL2MSLA032/MS11BFP11L3/BFP21L3AS 47DVM2LR2MSLA050 LAS 57DS3LG14RSA60 070 L3400AJ4 CC 1000 4PAJ4DD 1000-4PN1LGIR/N1LGILlight/med oilS6LG14RSA125 070 L3400AJ6 CC 1000 4PAJ6DD 1000-4PNN2LGIR/NN2LGILlight/med oilS6LG14RSA125 0770 L3410J7 CC 1000-4PNN3LGIR/NN3LGILlight/med oilPON 3E3 + J3 seriesPON 4E4 + J4 seriesPON 5E5 + J5 seriesPON 6E6 + J6 seriesUHE-A2TA2 seriesUHE-A3TA3 seriesUHE-A4TA4 seriesUHE-A5TA5 serieswww.anglonordic.co.uk

I100Copyright ANGLO NORDIC BURNER PRODUCTS LIMITED 2010Cross Reference & Conversion DataDelta V,VD & VM Fuel Pump Conversion Instructions- By-pass InstallationsDelta 'A/AD'Fuel Pump Conversion Instructions - By-pass InstallationsTo convert the DELTA fuel unit from the single pipe version to the two pipe version,do the following:a) Using a 6mm allen key, remove the 1/4" plug from return port (fig 1).b) Remove the 1/8" plug from the vacuum port.c) Using a 2.5mm allen key, insert & screw the by-pass plug in via the vacuum gauge port (fig 2).d) Screw back the 1/8" plug into the vacuum port.To convert the DELTA fuel unit from the two pipe version to the single pipe version,do the following:a) Remove the 1/8" plug from the vacuum port.b) Using a 2.5mm allen key, remove the by-pass plug via the vacuum gauge port (fig 2).c) Screw back the 1/8" plug into the vacuum port.d) Insert & screw a 1/4" plug into the return port (fig 1).To convert the DELTA fuel unit from the single pipe version to the two pipe version,do the following:a) Using a 19mm spanner, remove the 1/4" plug from the return port (fig 1).b) Located inside the return plug is the by-pass plug. Remove it with a 4mm Allen key (fig 2).c) Insert and screw the by-pass plug in the return port (fig 3).To convert the DELTA fuel unit from the two pipe version to the single pipe version,do the following:d) Using a 4mm allen key, unscrew the by-pass plug from the return port (fig 3).e) Insert & screw a 1/4" plug into the return port (fig 1).CAUTION: in the single pipe versions, the air is bled through the nozzle line, after the solenoid valve opening.CAUTION: in the two pipe versions, the air is bled through the return port. After conversion, the air must be bledmanually, through the pressure gauge connection.CAUTION: Make sure that the by-pass plug is not used in a single pipe installation because the fuel unit will notfunction properly & damage to both the pump & the burner motor could result.fig.1fig.2fig.3fig.1fig.2